ITEM | TYPE | SPECIFICATION | RTU5016 | RTU5017 | RTU5018 | RTU5019 |
INPUT | Digital | Dry contact, NC/NO | 2 | 2 | 2 | 2 |
Analog | 4-20mA,or 0-5V,or 0-20mA,10bits | / | 1 | / | 1 | |
Pulse Counter | Interval/total: 00000~99999 | 1 | / | / | 1 | |
Temperature | DS18B20, Accuracy:0.5*, detect range:-55~+125 Centigrade, -67 to +257 Fahrenheit) | / | / | 1 | 1 | |
OUTPUT | Digital | Dry contact Relay, capacity:250V/10A | 2 | 2 | 2 | 2 |
APP | Android | Download on our website | Yes | Yes | Yes | Yes |
iOS | Download iKeypad on APP STORE | Yes | Yes | Yes | Yes |
Parameter item | Reference scope |
DC Power supply | 8~24VDC 2A |
Power consumption | 12V input Max. 50mA/Average 50mA |
Frequency range | Dual band 900/1800 MHz (Default)or 850/1900Mhz(Optional) |
SIM Card | Supporting 3V SIM Card |
Antenna | 50 Ω SMA Antenna interface |
Temperature range | -20-+60 °C |
Humidity range | Relative humidity 90% (condensation free) |
Relay Output | 2, Dry Contact, NC or NO, 10A/240VAC |
Digital Input | 2, Dry Contact, NC or NO |
Pulse Input | 1, range is 00000~99999. |
Backup Battery | 900mAH, last 18hours |
Exterior dimension | 150mm*71mm*30.30mm |
Net Weight | 600 g |