FRP Septic Tank

Price:  

FRP Septic Tank
FRP septic tank refers to equipment made of synthetic resin as the matrix and glass fiber reinforced materials specially used for treating domestic sewage. FRP septic tank is a domestic sewage purification treatment equipment for civil buildings such as industrial enterprise living rooms and urban residential quarters. FRP septic tank temporarily stores excrement and makes it decompose initially in the tank to reduce the solid content in the discharged sewage.
FRP septic tank is mainly suitable for domestic sewage purification treatment in civil buildings such as industrial enterprise living quarters and urban residential quarters.

Cleaning well

1. The backfill meets the requirements of the construction specifications. A cleaning well (inspection well) can be built on the tank body. There are two types of cleaning wells: brick wells and prefabricated reinforced concrete wells.
2. In order to prevent leakage of the brick well wall, the inner and outer walls of the inspection well are required to be coated with waterproof mortar, with a thickness of 20mm (1:2 waterproof mortar, 5% waterproof agent of the internal reference cement weight), and 45 at the inner corner. Inclined surface, 50mm thick. When there is groundwater, apply two coats of hot asphalt (or other waterproof coating) on the outer wall of the well, and finally cover the soil to the ground level.

Construction precautions

1. When excavating the foundation trench, the geological conditions should be mastered.
2. The location and burial depth of the FRP septic tank should be strictly laid out and positioned according to the design requirements.
3. After the FRP septic tank is in place, the soil should be backfilled in time, and the tank body should be filled with water to prevent displacement. The backfill soil is required to be screened, without sharp stones and construction waste. When there is no groundwater, the soil density is 0.95 and compacted. Pay special attention to filling the surrounding area of ​​the tank body with plain soil or yellow sand: when there is groundwater, fill the tank body with plain soil or yellow sand, and the fixed position of the tank body is evenly stressed.
4. During construction in the rainy season, drainage facilities should be available to prevent water accumulation in the foundation pit and slope collapse. At the same time, fill the tank body with water to prevent floating and displacement.
5. The construction should be carried out in accordance with the relevant engineering construction and acceptance specifications.

Advantages:

1. Save money
The FRP septic tank is produced in a factory, mechanized, batch, and integral shape, using new processes and new materials. It has a small size and a large effective volume.
2. Save labor and time
The FRP septic tank is integrally shaped, light and strong, and quick and easy to install.
3. Save land
The FRP septic tank saves land excavation area.
4. High efficiency
The FRP septic tank has good sealing performance and can efficiently treat feces. The anaerobic decay effect is more than 2 times better than that of traditional septic tanks.
5. Environmental protection
The FRP septic tank is produced in an integral shape, with good sealing performance, no leakage, no pollution of surface water, and no corrosion of flowers, trees, wires and cables around the septic tank. The pool uses high-level siphon drainage, multiple sedimentation, and multiple purification.
6. Durable
The FRP septic tank is made of new material FRP, which is resistant to aging, acid and alkali, and has a service life of more than 50 years.
7. High pressure resistance and compressive strength
GRP septic tank is international 50 steel resin sealed and cylindrical, which has several times higher compressive strength than polygonal and square ones.
8. No post-management and long slag removal cycle
GRP septic tank is buried, unpowered, and does not require maintenance or management in the later stage.

How to use

1. The selection of GRP septic tank is based on different buildings, and the design parameters are calculated by the single project designer.
2. The location of GRP septic tank should not affect the building foundation in principle; generally, the distance from the drinking water pool should not be less than 10m. The distance from the underground water intake structure should not be less than 30m. When the building foundation plane is higher than the septic tank foundation plane, the distance from the outer wall of the septic tank should not be less than 2m. When the building foundation plane is lower than the septic tank foundation plane, the net distance between the outer wall of the septic tank and the outer wall of the building should not be less than 5m.
3. The minimum soil cover of the overall GRP septic tank is 0.3m. The maximum soil cover should not exceed 3m. In cold areas, when the minimum temperature is below -10℃, the soil depth of the septic tank shall not be less than 12m. In areas where the average temperature in the coldest month is less than -13℃, when considering the setting depth of the FRP septic tank, the FRP septic tank should be set below the freezing line in the area.
4. The FRP septic tank is installed under the green belt, lawn, and sidewalk, and the soil cover should not exceed 1.5m; it can also be installed on the road.
5. Manhole cover: When there is no car passing, a locked light double-layer manhole cover and cover seat are used; when a car can pass, a locked heavy double-layer is used. The FRP septic tank also takes into account the needs of community greening or road square paving. The cast iron or polymer manhole cover is level with the ground. In the paved ground, the manhole cover can be appropriately lowered to the paved floor tiles. When the paved floor tiles on the manhole cover must be opened when the manhole cover needs to be opened.
6. If the volume of the FRP septic tank exceeds 50 m³, two single tanks can be connected in parallel or in series. If connected in series, the designer and the user must notify the manufacturer in advance for pre-setting, and the distance between the outer walls of the tanks must not be less than 500 mm.