Contact person: Mr. Maple
Position:
Address: No.298 Zhonghua north Street
Country: China
Phone: 86 311 80690567 - Mobi:

Shielding Mesh Tape

Price:  

Material: Tinned Copper,Copper clad steel,Copper Clad Iron,Nickel,Monel etc. We can design it according to customer’s requests.
Shielding Tape
Normal Specification:
width: 1-6 inch,  length: 20m,8m , 16.5m etc
It also can be designed according equipment.

Product Description:
Electrical Shielding Tape is an all-metal,open-weave, shielding braid tape in a flat, cable-like form. It is conformable due to the open-weave knit construction of two No. 36 AWG tinned copper wires.
Conducting metal tape must be woven of No. 36 AWG tinned copper wire and be capable of operating at the emergency cable temperature of 130centidegree /266 degree F. It must be usable uncovered, indoors and outdoors, in a highly stretched condition without corroding, tearing or splitting. It must be nonflammable and be compatible with cable oils, common solvents, adhesives, and high-voltage splicing and terminating insulations.

Features:
-Tinned copper conductors
-Stable at elevated temperatures
-Oil Resistant
-Compatible with power cable insulations
-Fire resistant
-Elongates easily to conform to inclined or uneven
surfaces. Corrosion resistant
-Compatible with all high-voltage splicing and
-termination materials Unaffected by solvents, U.V., ozone, and moisture
-Because of its construction, the tape interlocks
-with the previous layer, thereby assuring a tighter
wrap (no solder bead is required)
The porosity of Scotch 24 Tape will permit
-complete resin saturation when splicing
Usable for indoor and outdoor applications

Applications
• To provide shielding for cable joints on shielded power cables
• To make the conductive portion of the stress cone on power cable terminations
• To smooth connector area in oil-filled cables
METHODS OF APPLYING EMC SHIELDING TAPE EMC SHIELDING TAPE
Should be wrapped around the cable assembly. Wrap the main cable and terminate the tape before beginning to wrap  the cable branch . Start and end all helical wrapping with a minimum of wro overlapping circumferential wraps . At branch connections., start at least 4 in (100mm) before and after branch to assure adequate EMC SHIELDING TAPE  coverage at the "V" section. Branch connections should not be designed to occur within 4 in (100mm) or each other .
Recommended lead for most applications is 0.50 in. (13mm) , although some additional shielding will be achieved when utilizing a  0.25in.(6mm) lead The length of EMC SHIELDING TAPE required for each cable using theres two types of lead wraps can be obtained by referring to Figure 2.
SEND INQUIRY
Please fill in fully your information to send email
Your name*
Email*
Company
Address*
Country*
Phone*
Content*
RELATED PRODUCTS RELATED PRODUCTS