| Main technical parameters | |
| Working voltage range | 90VAC ~ 120VAC |
| Rated voltage | 120VAC 60Hz |
| Power frequency | 50/60Hz±5% |
| Rated frequency | 50Hz |
| Dielectric strength(V/1min) | 1800V, 0.5mA, 3S |
| Working ambient temperature | -10℃~70℃ |
| Ambient temperature | -20℃~70℃ |
| Life cycle | ≥50,000 times |
| Temperature setting range | 35-65℃ |
| High temperature protection | when the output water temperature ≥85℃ for 3S |
| Pre- cleaning time | 2S |
| After cleaning time | 20s |
| Start-up water flow | ≤3L/min |
| Closing water flow | ≤2.5L/min |
| Ignition time | 8±1S |
| Cleaning time before 2nd ignition | 3S |
| Max. allowable No. of ignition | 2 |
| Valve moving pulse | 0.5±0.05S |
| 24V Valve open voltage | ≥24V |
| 24V Valve holding voltage | ≥8.5V |
| Output voltage of switch power supply | 5VDC (with 300mA working current) |
| 30±1.5VDC(with 510mA working current) | |
| 12±1VDC(with 110mA working current) | |
| Ion sensibility of flame detection | ≥5.1MΩ |
| Temperature detection precision | ±2℃ |
| Waiting time of reaching setted temperature | ≤35S |
| Water temperature overshoot range | ±3℃ |
| Timing tolerance | ±1 minutes |
| Post-purge time | 20±2s |
| Time to achieve safe shut down | <1s |
| Trial for ignition period | 7.5±1s |